This documentation is for an out-of-date version of Apache Flink. We recommend you use the latest stable version.

Debugging Classloading

When running Flink applications, the JVM will load various classes over time. These classes can be divided into two domains:

  • The Java Classpath: This is Java’s common classpath, and it includes the JDK libraries, and all code in Flink’s /lib folder (the classes of Apache Flink and its core dependencies).

  • The Dynamic User Code: These are all classes that are included in the JAR files of dynamically submitted jobs, (via REST, CLI, web UI). They are loaded (and unloaded) dynamically per job.

What classes are part of which domain depends on the particular setup in which you run Apache Flink. As a general rule, whenever you start the Flink processes first, and the submit jobs, the job’s classes are loaded dynamically. If the Flink processes are started together with the job/application, or the application spawns the Flink components (JobManager, TaskManager, etc.) then all classes are in the Java classpath.

In the following are some more details about the different deployment modes:

Standalone Session

When starting a Flink cluster as a standalone session, the JobManagers and TaskManagers are started with the Flink framework classes in the Java classpath. The classes from all jobs/applications that are submitted against the session (via REST / CLI) are loaded dynamically.

Docker / Kubernetes Sessions

Docker / Kubernetes setups that start first a set of JobManagers / TaskManagers and then submit jobs/applications via REST or the CLI behave like standalone sessions: Flink’s code is in the Java classpath, the job’s code is loaded dynamically.

YARN

YARN classloading differs between single job deployments and sessions:

  • When submitting a Flink job/application directly to YARN (via bin/flink run -m yarn-cluster ...), dedicated TaskManagers and JobManagers are started for that job. Those JVMs have both Flink framework classes and user code classes in the Java classpath. That means that there is no dynamic classloading involved in that case.

  • When starting a YARN session, the JobManagers and TaskManagers are started with the Flink framework classes in the classpath. The classes from all jobs that are submitted against the session are loaded dynamically.

Mesos

Mesos setups following this documentation currently behave very much like the a YARN session: The TaskManager and JobManager processes are started with the Flink framework classes in the Java classpath, job classes are loaded dynamically when the jobs are submitted.

Inverted Class Loading and ClassLoader Resolution Order

In setups where dynamic classloading is involved (sessions), there is a hierarchy of typically two ClassLoaders: (1) Java’s application classloader, which has all classes in the classpath, and (2) the dynamic user code classloader. for loading classes from the user-code jar(s). The user-code ClassLoader has the application classloader as its parent. cases.

By default, Flink inverts classloading order, meaning it looks into the user code classloader first, and only looks into the parent (application classloader) if the class is not part of the dynamically loaded user code.

The benefit of inverted classloading is that jobs can use different library versions than Flink’s core itself, which is very useful when the different versions of the libraries are not compatible. The mechanism helps to avoid the common dependency conflict errors like IllegalAccessError or NoSuchMethodError. Different parts of the code simply have separate copies of the classes (Flink’s core or one of its dependencies can use a different copy than the user code). In most cases, this work well and no additional configuration from the user is needed.

However, there are cases when the inverted classloading causes problems (see below, “X cannot be cast to X”). You can revert back to Java’s default mode by configuring the ClassLoader resolution order via classloader.resolve-order in the Flink config to parent-first (from Flink’s default child-first).

Please note that certain classes are always resolved in a parent-first way (through the parent ClassLoader first), because they are shared between Flink’s core and the user code or the user-code facing APIs. The packages for these classes are configured via classloader.parent-first-patterns-default and classloader.parent-first-patterns-additional. To add new packages to be parent-first loaded, please set the classloader.parent-first-patterns-additional config option.

Avoiding Dynamic Classloading

All components (JobManger, TaskManager, Client, ApplicationMaster, …) log their classpath setting on startup. They can be found as part of the environment information at the beginning of the log.

When running a setup where the Flink JobManager and TaskManagers are exclusive to one particular job, one can put JAR files directly into the /lib folder to make sure they are part of the classpath and not loaded dynamically.

It usually works to put the job’s JAR file into the /lib directory. The JAR will be part of both the classpath (the AppClassLoader) and the dynamic class loader (FlinkUserCodeClassLoader). Because the AppClassLoader is the parent of the FlinkUserCodeClassLoader (and Java loads parent-first, by default), this should result in classes being loaded only once.

For setups where the job’s JAR file cannot be put to the /lib folder (for example because the setup is a session that is used by multiple jobs), it may still be possible to put common libraries to the /lib folder, and avoid dynamic class loading for those.

Manual Classloading in the Job

In some cases, a transformation function, source, or sink needs to manually load classes (dynamically via reflection). To do that, it needs the classloader that has access to the job’s classes.

In that case, the functions (or sources or sinks) can be made a RichFunction (for example RichMapFunction or RichWindowFunction) and access the user code class loader via getRuntimeContext().getUserCodeClassLoader().

X cannot be cast to X exceptions

In setups with dynamic classloading, you may see an exception in the style com.foo.X cannot be cast to com.foo.X. This means that multiple versions of the class com.foo.X have been loaded by different class loaders, and types of that class are attempted to be assigned to each other.

One common reason is that a library is not compatible with Flink’s inverted classloading approach. You can turn off inverted classloading to verify this (set classloader.resolve-order: parent-first in the Flink config) or exclude the library from inverted classloading (set classloader.parent-first-patterns-additional in the Flink config).

Another cause can be cached object instances, as produced by some libraries like Apache Avro, or by interning objects (for example via Guava’s Interners). The solution here is to either have a setup without any dynamic classloading, or to make sure that the respective library is fully part of the dynamically loaded code. The latter means that the library must not be added to Flink’s /lib folder, but must be part of the application’s fat-jar/uber-jar

Unloading of Dynamically Loaded Classes

All scenarios that involve dynamic class loading (sessions) rely on classes being unloaded again. Class unloading means that the Garbage Collector finds that no objects from a class exist and more, and thus removes the class (the code, static variable, metadata, etc).

Whenever a TaskManager starts (or restarts) a task, it will load that specific task’s code. Unless classes can be unloaded, this will become a memory leak, as new versions of classes are loaded and the total number of loaded classes accumulates over time. This typically manifests itself though a OutOfMemoryError: Metaspace.

Common causes for class leaks and suggested fixes:

  • Lingering Threads: Make sure the application functions/sources/sinks shuts down all threads. Lingering threads cost resources themselves and additionally typically hold references to (user code) objects, preventing garbage collection and unloading of the classes.

  • Interners: Avoid caching objects in special structures that live beyond the lifetime of the functions/sources/sinks. Examples are Guava’s interners, or Avro’s class/object caches in the serializers.

A way to address dependency conflicts from the application developer’s side is to avoid exposing dependencies by shading them away.

Apache Maven offers the maven-shade-plugin, which allows one to change the package of a class after compiling it (so the code you are writing is not affected by the shading). For example if you have the com.amazonaws packages from the aws sdk in your user code jar, the shade plugin would relocate them into the org.myorg.shaded.com.amazonaws package, so that your code is calling your aws sdk version.

This documentation page explains relocating classes using the shade plugin.

Note that most of Flink’s dependencies, such as guava, netty, jackson, etc. are shaded away by the maintainers of Flink, so users usually don’t have to worry about it.

Back to top