Release Notes - Flink 1.10

Release Notes - Flink 1.10 #

These release notes discuss important aspects, such as configuration, behavior, or dependencies, that changed between Flink 1.9 and Flink 1.10. Please read these notes carefully if you are planning to upgrade your Flink version to 1.10.

Clusters & Deployment #

FileSystems should be loaded via Plugin Architecture #

s3-hadoop and s3-presto filesystems do no longer use class relocations and need to be loaded through plugins but now seamlessly integrate with all credential providers. Other filesystems are strongly recommended to be only used as plugins as we will continue to remove relocations.

The Flink client now also respects the configured classloading policy, i.e., parent-first or child-first classloading. Previously, only cluster components such as the job manager or task manager supported this setting. This does mean that users might get different behaviour in their programs, in which case they should configure the classloading policy explicitly to use parent-first classloading, which was the previous (hard-coded) behaviour.

Enable spreading out Tasks evenly across all TaskManagers #

When FLIP-6 was rolled out with Flink 1.5.0, we changed how slots are allocated from TaskManagers (TMs). Instead of evenly allocating the slots from all registered TMs, we had the tendency to exhaust a TM before using another one. To use a scheduling strategy that is more similar to the pre-FLIP-6 behaviour, where Flink tries to spread out the workload across all currently available TMs, one can set cluster.evenly-spread-out-slots: true in the flink-conf.yaml.

Directory Structure Change for highly available Artifacts #

All highly available artifacts stored by Flink will now be stored under HA_STORAGE_DIR/HA_CLUSTER_ID with HA_STORAGE_DIR configured by high-availability.storageDir and HA_CLUSTER_ID configured by high-availability.cluster-id.

Resources and JARs shipped via –yarnship will be ordered in the Classpath #

When using the --yarnship command line option, resource directories and jar files will be added to the classpath in lexicographical order with resources directories appearing first.

Removal of –yn/–yarncontainer Command Line Options #

The Flink CLI no longer supports the deprecated command line options -yn/--yarncontainer, which were used to specify the number of containers to start on YARN. This option has been deprecated since the introduction of FLIP-6. All Flink users are advised to remove this command line option.

Removal of –yst/–yarnstreaming Command Line Options #

The Flink CLI no longer supports the deprecated command line options -yst/--yarnstreaming, which were used to disable eager pre-allocation of memory. All Flink users are advised to remove this command line option.

Mesos Integration will reject expired Offers faster #

Flink’s Mesos integration now rejects all expired offers instead of only 4. This improves the situation where Fenzo holds on to a lot of expired offers without giving them back to the Mesos resource manager.

Scheduler Rearchitecture #

Flink’s scheduler was refactored with the goal of making scheduling strategies customizable in the future. Using the legacy scheduler is discouraged as it will be removed in a future release. However, users that experience issues related to scheduling can fallback to the legacy scheduler by setting jobmanager.scheduler to legacy in their flink-conf.yaml for the time being. Note, however, that using the legacy scheduler with the Pipelined Region Failover Strategy enabled has the following caveats:

  • Exceptions that caused a job to restart will not be shown on the job overview page of the Web UI

. However, exceptions that cause a job to fail (e.g., when all restart attempts exhausted) will still be shown.

  • The uptime metric will not be reset after restarting a job due to task failure

.

Note that in the default flink-conf.yaml, the Pipelined Region Failover Strategy is already enabled. That is, users that want to use the legacy scheduler and cannot accept aforementioned caveats should make sure that jobmanager.execution.failover-strategy is set to full or not set at all.

Java 11 Support #

Beginning from this release, Flink can be compiled and run with Java 11. All Java 8 artifacts can be also used with Java 11. This means that users that want to run Flink with Java 11 do not have to compile Flink themselves.

When starting Flink with Java 11, the following warnings may be logged:

WARNING: An illegal reflective access operation has occurred
WARNING: Illegal reflective access by org.apache.flink.core.memory.MemoryUtils (file:/opt/flink/flink-1.10.0/lib/flink-dist_2.11-1.10.0.jar) to constructor java.nio.DirectByteBuffer(long,int)
WARNING: Please consider reporting this to the maintainers of org.apache.flink.core.memory.MemoryUtils
WARNING: Use --illegal-access=warn to enable warnings of further illegal reflective access operations
WARNING: All illegal access operations will be denied in a future release

WARNING: An illegal reflective access operation has occurred
WARNING: Illegal reflective access by org.apache.flink.api.java.ClosureCleaner (file:/home/flinkuser/.m2/repository/org/apache/flink/flink-core/1.10.0/flink-core-1.10.0.jar) to field java.lang.String.value
WARNING: Please consider reporting this to the maintainers of org.apache.flink.api.java.ClosureCleaner
WARNING: Use --illegal-access=warn to enable warnings of further illegal reflective access operations
WARNING: All illegal access operations will be denied in a future release

WARNING: An illegal reflective access operation has occurred
WARNING: Illegal reflective access by org.jboss.netty.util.internal.ByteBufferUtil (file:/home/flinkuser/.m2/repository/io/netty/netty/3.10.6.Final/netty-3.10.6.Final.jar) to method java.nio.DirectByteBuffer.cleaner()
WARNING: Please consider reporting this to the maintainers of org.jboss.netty.util.internal.ByteBufferUtil
WARNING: Use --illegal-access=warn to enable warnings of further illegal reflective access operations
WARNING: All illegal access operations will be denied in a future release

WARNING: An illegal reflective access operation has occurred
WARNING: Illegal reflective access by com.esotericsoftware.kryo.util.UnsafeUtil (file:/home/flinkuser/.m2/repository/com/esotericsoftware/kryo/kryo/2.24.0/kryo-2.24.0.jar) to constructor java.nio.DirectByteBuffer(long,int,java.lang.Object)
WARNING: Please consider reporting this to the maintainers of com.esotericsoftware.kryo.util.UnsafeUtil
WARNING: Use --illegal-access=warn to enable warnings of further illegal reflective access operations
WARNING: All illegal access operations will be denied in a future release

These warnings are considered harmless and will be addressed in future Flink releases.

Lastly, note that the connectors for Cassandra, Hive, HBase, and Kafka 0.8–0.11 have not been tested with Java 11 because the respective projects did not provide Java 11 support at the time of the Flink 1.10.0 release.

Memory Management #

New Task Executor Memory Model #

With FLIP-49, a new memory model has been introduced for the task executor. New configuration options have been introduced to control the memory consumption of the task executor process. This affects all types of deployments: standalone, YARN, Mesos, and the new active Kubernetes integration. The memory model of the job manager process has not been changed yet but it is planned to be updated as well.

If you try to reuse your previous Flink configuration without any adjustments, the new memory model can result in differently computed memory parameters for the JVM and, thus, performance changes.

Please, check the user documentation for more details.

Deprecation and breaking changes #

The following options have been removed and have no effect anymore:

Deprecated/removed config option Note
taskmanager.memory.fraction Check also the description of the new option taskmanager.memory.managed.fraction but it has different semantics and the value of the deprecated option usually has to be adjusted
taskmanager.memory.off-heap Support for on-heap managed memory has been removed, leaving off-heap managed memory as the only possibility
taskmanager.memory.preallocate Pre-allocation is no longer supported, and managed memory is always allocated lazily

The following options, if used, are interpreted as other new options in order to maintain backwards compatibility where it makes sense:

Deprecated config option Interpreted as
taskmanager.heap.size
  • taskmanager.memory.flink.size for standalone deployment
  • taskmanager.memory.process.size for containerized deployments
taskmanager.memory.size taskmanager.memory.managed.size
taskmanager.network.memory.min taskmanager.memory.network.min
taskmanager.network.memory.max taskmanager.memory.network.max
taskmanager.network.memory.fraction taskmanager.memory.network.fraction

The container cut-off configuration options, containerized.heap-cutoff-ratio and containerized.heap-cutoff-min, have no effect for task executor processes anymore but they still have the same semantics for the JobManager process.

RocksDB State Backend Memory Control #

Together with the introduction of the new Task Executor Memory Model, the memory consumption of the RocksDB state backend will be limited by the total amount of Flink Managed Memory, which can be configured via taskmanager.memory.managed.size or taskmanager.memory.managed.fraction. Furthermore, users can tune RocksDB’s write/read memory ratio (state.backend.rocksdb.memory.write-buffer-ratio, by default 0.5) and the reserved memory fraction for indices/filters (state.backend.rocksdb.memory.high-prio-pool-ratio, by default 0.1). More details and advanced configuration options can be found in the Flink user documentation.

Fine-grained Operator Resource Management #

Config options table.exec.resource.external-buffer-memory, table.exec.resource.hash-agg.memory, table.exec.resource.hash-join.memory, and table.exec.resource.sort.memory have been deprecated. Beginning from Flink 1.10, these config options are interpreted as weight hints instead of absolute memory requirements. Flink choses sensible default weight hints which should not be adjustment by users.

Table API & SQL #

Rename of ANY Type to RAW Type #

The identifier raw is a reserved keyword now and must be escaped with backticks when used as a SQL field or function name.

Rename of Table Connector Properties #

Some indexed properties for table connectors have been flattened and renamed for a better user experience when writing DDL statements. This affects the Kafka Connector properties connector.properties and connector.specific-offsets. Furthermore, the Elasticsearch Connector property connector.hosts is affected. The aforementioned, old properties are deprecated and will be removed in future versions. Please consult the Table Connectors documentation for the new property names.

Methods for interacting with temporary Tables & Views #

Methods registerTable()/registerDataStream()/registerDataSet() have been deprecated in favor of createTemporaryView(), which better adheres to the corresponding SQL term.

The scan() method has been deprecated in favor of the from() method.

Methods registerTableSource()/registerTableSink() become deprecated in favor of ConnectTableDescriptor#createTemporaryTable(). The ConnectTableDescriptor approach expects only a set of string properties as a description of a TableSource or TableSink instead of an instance of a class in case of the deprecated methods. This in return makes it possible to reliably store those definitions in catalogs.

Method insertInto(String path, String... pathContinued) has been removed in favor of in insertInto(String path).

All the newly introduced methods accept a String identifier which will be parsed into a 3-part identifier. The parser supports quoting the identifier. It also requires escaping any reserved SQL keywords.

Removal of ExternalCatalog API #

The deprecated ExternalCatalog API has been dropped. This includes:

  • ExternalCatalog (and all dependent classes, e.g., ExternalTable)
  • SchematicDescriptor, MetadataDescriptor, StatisticsDescriptor

Users are advised to use the new Catalog API.

Configuration #

Introduction of Type Information for ConfigOptions #

Getters of org.apache.flink.configuration.Configuration throw IllegalArgumentException now if the configured value cannot be parsed into the required type. In previous Flink releases the default value was returned in such cases.

Increase of default Restart Delay #

The default restart delay for all shipped restart strategies, i.e., fixed-delay and failure-rate, has been raised to 1 s (from originally 0 s).

Simplification of Cluster-Level Restart Strategy Configuration #

Previously, if the user had set restart-strategy.fixed-delay.attempts or restart-strategy.fixed-delay.delay but had not configured the option restart-strategy, the cluster-level restart strategy would have been fixed-delay. Now the cluster-level restart strategy is only determined by the config option restart-strategy and whether checkpointing is enabled. See “Task Failure Recovery” for details.

Disable memory-mapped BoundedBlockingSubpartition by default #

The config option taskmanager.network.bounded-blocking-subpartition-type has been renamed to taskmanager.network.blocking-shuffle.type. Moreover, the default value of the aforementioned config option has been changed from auto to file. The reason is that TaskManagers running on YARN with auto, could easily exceed the memory budget of their container, due to incorrectly accounted memory-mapped files memory usage.

Removal of non-credit-based Network Flow Control #

The non-credit-based network flow control code was removed alongside of the configuration option taskmanager.network.credit-model. Flink will now always use credit-based flow control.

Removal of HighAvailabilityOptions#HA_JOB_DELAY #

The configuration option high-availability.job.delay has been removed since it is no longer used.

State #

Enable Background Cleanup of State with TTL by default #

Background cleanup of expired state with TTL is activated by default now for all state backends shipped with Flink. Note that the RocksDB state backend implements background cleanup by employing a compaction filter. This has the caveat that even if a Flink job does not store state with TTL, a minor performance penalty during compaction is incurred. Users that experience noticeable performance degradation during RocksDB compaction can disable the TTL compaction filter by setting the config option state.backend.rocksdb.ttl.compaction.filter.enabled to false.

Deprecation of StateTtlConfig#Builder#cleanupInBackground() #

StateTtlConfig#Builder#cleanupInBackground() has been deprecated because the background cleanup of state with TTL is already enabled by default.

Timers are stored in RocksDB by default when using RocksDBStateBackend #

The default timer store has been changed from Heap to RocksDB for the RocksDB state backend to support asynchronous snapshots for timer state and better scalability, with less than 5% performance cost. Users that find the performance decline critical can set state.backend.rocksdb.timer-service.factory to HEAP in flink-conf.yaml to restore the old behavior.

Removal of StateTtlConfig#TimeCharacteristic #

StateTtlConfig#TimeCharacteristic has been removed in favor of StateTtlConfig#TtlTimeCharacteristic.

New efficient Method to check if MapState is empty #

We have added a new method MapState#isEmpty() which enables users to check whether a map state is empty. The new method is 40% faster than mapState.keys().iterator().hasNext() when using the RocksDB state backend.

RocksDB Upgrade #

We have again released our own RocksDB build (FRocksDB) which is based on RocksDB version 5.17.2 with several feature backports for the Write Buffer Manager to enable limiting RocksDB’s memory usage. The decision to release our own RocksDB build was made because later RocksDB versions suffer from a performance regression under certain workloads.

RocksDB Logging disabled by default #

Logging in RocksDB (e.g., logging related to flush, compaction, memtable creation, etc.) has been disabled by default to prevent disk space from being filled up unexpectedly. Users that need to enable logging should implement their own RocksDBOptionsFactory that creates DBOptions instances with InfoLogLevel set to INFO_LEVEL.

Improved RocksDB Savepoint Recovery #

In previous Flink releases users may encounter an OutOfMemoryError when restoring from a RocksDB savepoint containing large KV pairs. For that reason we introduced a configurable memory limit in the RocksDBWriteBatchWrapper with a default value of 2 MB. RocksDB’s WriteBatch will flush before the consumed memory limit is reached. If needed, the limit can be tuned via the state.backend.rocksdb.write-batch-size config option in flink-conf.yaml.

Python 2 Support dropped #

Beginning from this release, PyFlink does not support Python 2. This is because Python 2 has reached end of life on January 1, 2020, and several third-party projects that PyFlink depends on are also dropping Python 2 support.

Monitoring #

InfluxdbReporter skips Inf and NaN #

The InfluxdbReporter now silently skips values that are unsupported by InfluxDB, such as Double.POSITIVE_INFINITY, Double.NEGATIVE_INFINITY, Double.NaN, etc.

Connectors #

Kinesis Connector License Change #

flink-connector-kinesis is now licensed under the Apache License, Version 2.0, and its artifacts will be deployed to Maven central as part of the Flink releases. Users no longer need to build the Kinesis connector from source themselves.

Miscellaneous Interface Changes #

ExecutionConfig#getGlobalJobParameters() cannot return null anymore #

ExecutionConfig#getGlobalJobParameters has been changed to never return null. Conversely, ExecutionConfig#setGlobalJobParameters(GlobalJobParameters) will not accept null values anymore.

Change of contract in MasterTriggerRestoreHook interface #

Implementations of MasterTriggerRestoreHook#triggerCheckpoint(long, long, Executor) must be non-blocking now. Any blocking operation should be executed asynchronously, e.g., using the given executor.

Client-/ and Server-Side Separation of HA Services #

The HighAvailabilityServices have been split up into client-side ClientHighAvailabilityServices and cluster-side HighAvailabilityServices. When implementing custom high availability services, users should follow this separation by overriding the factory method HighAvailabilityServicesFactory#createClientHAServices(Configuration). Moreover, HighAvailabilityServices#getWebMonitorLeaderRetriever() should no longer be implemented since it has been deprecated.

Deprecation of HighAvailabilityServices#getWebMonitorLeaderElectionService() #

Implementations of HighAvailabilityServices should implement HighAvailabilityServices#getClusterRestEndpointLeaderElectionService() instead of HighAvailabilityServices#getWebMonitorLeaderElectionService().

Interface Change in LeaderElectionService #

LeaderElectionService#confirmLeadership(UUID, String) now takes an additional second argument, which is the address under which the leader will be reachable. All custom LeaderElectionService implementations will need to be updated accordingly.

Deprecation of Checkpoint Lock #

The method org.apache.flink.streaming.runtime.tasks.StreamTask#getCheckpointLock() is deprecated now. Users should use MailboxExecutor to run actions that require synchronization with the task’s thread (e.g. collecting output produced by an external thread). The methods MailboxExecutor#yield() or MailboxExecutor#tryYield() can be used for actions that need to give up control to other actions temporarily, e.g., if the current operator is blocked. The MailboxExecutor can be accessed by using YieldingOperatorFactory (see AsyncWaitOperator for an example usage).

Deprecation of OptionsFactory and ConfigurableOptionsFactory interfaces #

Interfaces OptionsFactory and ConfigurableOptionsFactory have been deprecated in favor of RocksDBOptionsFactory and ConfigurableRocksDBOptionsFactory, respectively.

Incompatibility of serialized JobGraphs #

Serialized JobGraphs which set the ResourceSpec created by Flink versions < 1.10 are no longer compatible with Flink >= 1.10. If you want to migrate these jobs to Flink >= 1.10 you will have to stop the job with a savepoint and then resume it from this savepoint on the Flink >= 1.10 cluster.